An H beam has parallel, wider flanges and carries bending and compression better per kilo β it is the default choice for columns, bridges and modern buildings. An I beam (S-shape / GB ε·₯ει’) has tapered, narrower flanges and suits lighter floor beams and edging. In export trade "H beam" covers ASTM W series, European IPE/HEA/HEB and GB HW/HM/HN; I beam means the older S-shape or GB 10#β40# sections. When in doubt, order the H beam β availability, size range and connection convenience are all better. Nikasteel supplies both, MOQ 5 tons, EN 10204 3.1 MTC with every order.
Buyers ask this daily: the two sections look similar in cross-section, but they behave differently under load, come from different rolling standards, and are quoted from different size tables. Here is the practical difference β and how to specify the right one on your next purchase order.
The Core Difference: Flange Geometry
| Feature | H Beam (W / IPE / HEA / HW-HM-HN) | I Beam (S-shape / GB ε·₯ει’) |
|---|---|---|
| Flange shape | Parallel (flat) inner and outer faces | Tapered (sloped) inner flange faces |
| Flange width | Wide β up to roughly equal to section depth | Narrow relative to depth |
| Web | Thicker, stiffer | Thinner |
| Bending efficiency | High section modulus per kg β best for beams & columns | Lower β fine for light floor loads |
| Connections | Flat flanges bolt easily to plates and other members | Sloped flanges need wedges/shims |
| Size range | Very wide (W4βW36, IPE/HEA/HEB 100β600, HW/HM/HN) | Limited rolled sizes (GB 10#β63#, S3βS24) |
| Typical use | Columns, bridges, high-rises, platforms, racking | Light floor beams, mezzanines, edging, machinery frames |
Weight per Meter: Quick Reference
Weight drives both price and freight. Common sizes (β kg/m):
| Size class | Light β | Medium β | Heavy β |
|---|---|---|---|
| ASTM W series | W6Γ9 β 13 kg/m | W10Γ33 β 49 kg/m | W21Γ101 β 150 kg/m |
| IPE (Europe) | IPE 140 β 12.9 | IPE 300 β 42.2 | IPE 600 β 122 |
| HEA / HEB (Europe) | HEA 200 β 42.3 | HEB 200 β 61.3 | HEB 300 β 117 |
| GB Hει’ (HW/HM/HN) | HN 200Γ100 β 21.7 | HM 294Γ200 β 57.3 | HW 300Γ300 β 94.5 |
| GB ε·₯ει’ (I beam) | 10# β 11.2 | 20# β 27.9 | 32# β 52.7 |
Full theoretical weight tables per size are in our H beam size chart. Weights are theoretical (from section dimensions Γ 7.85 t/mΒ³); invoice weight is the mill's weighed weight, typically within Β±2β4% tolerance.
Which Is Stronger: H Beam or I Beam?
The honest engineering answer: neither is universally "stronger" β per kilogram of steel, the deeper section wins in vertical bending, while the wider-flange H beam wins in stability and bidirectional loading. Here is what actually drives the difference:
| Loading Condition | Typical Winner | Why |
|---|---|---|
| Vertical bending (roof/floor loads) | Deeper I beam (e.g. IPE 400 vs HEA 400 at equal depth) | More of the material is concentrated in the flanges away from the neutral axis at the same weight class |
| Column / compression use | H beam (HEA/HEB/W) | Wide flanges give a larger radius of gyration about both axes β resists buckling in both directions |
| Side (lateral) loads, wind, seismic | H beam | Weak-axis stiffness is much higher with wide flanges |
| Connection simplicity | H beam (W/HEB) | Flange surfaces parallel and wide β easier bolting, no taper |
So an I beam is not "stronger" than an H beam β it packs its steel more efficiently for one direction of bending. Structural engineers pick the section by load direction, unbraced length and connection type, not by which shape sounds tougher. If you are substituting one for the other, have the change verified by the project engineer β see full H/I beam specifications and grades β
When to Choose Which
- Choose H beam when: the member is a column, carries heavy or long-span loads, needs bolted connections, or you want the widest choice of sizes and best availability. 90% of export orders are H beam.
- Choose I beam when: spans are short and loads light, your local market prices I beam attractively, or existing structures are I beam and you are extending them.
- Replacing I beam with H beam: pick an H beam of equal or greater depth and section modulus; flat flanges actually simplify the connection. On code-governed projects, have the engineer sign off.
Grades Are the Same β Specify the Standard
Both sections are rolled in the same structural grades: ASTM A36, A572 Gr50, A992; EN S235JRβS355JR; JIS SS400, SM490; GB Q235B, Q355B. Anchor the PO to one named standard and require the EN 10204 3.1 mill certificate to match β the full equivalence table is in our steel buying guide.
FAQ β What Buyers Ask
Which is stronger, H beam or I beam?
Per kilo of steel, the H beam wins in bending and compression β wider parallel flanges give a higher section modulus. That's why columns and bridges are H beam.
What does W12Γ26 mean?
Nominal depth 12 inches, 26 lb/ft (β38.7 kg/m). Nikasteel supplies W4Γ13 β W36Γ230 in A36/A572 Gr50/A992.
Is H beam pricier?
Per ton, prices are close and move with the mills. H beam's advantage is availability and size choice; I beam's limited rolled sizes can slow small orders.
Surface options?
Black, red oxide primer, hot-dip galvanized, or shot-blasted SA2.5 + 60β80 Β΅m epoxy primer β cut to length 6/9/12 m or custom.
Mixed container possible?
Yes β beams, plates, angles and pipes can share one container. Trial orders from 5 tons.
How fast can you ship?
7β15 days for stocked sizes, 20β30 days for mill production, EXW ex-mill & FOB Huangpu / Nansha / Shekou.
About the Source
Foshan Nikasteel International Trade Co., Ltd. β a China-based steel exporter in Foshan, Guangdong, supplying H beam, I beam, plates and coated coils to 50+ countries since 2016, with EN 10204 3.1 mill certificates on every order and SGS/BV/TUV inspection on request.
- π§ [email protected] Β· WhatsApp/Phone: +86 191 5745 8011
- π Foshan City, Guangdong Province, China Β· MonβSat 8:30β18:30 (GMT+8)
Get a Beam Quotation in 24 Hours